Troubleshooting Cisco Data Center Infrastructure (DCIT) v6.0

QUESTION 31

What is the default number of dynamic vNICs that is specified by the Cisco UCS Manager when creating a dynamic vNIC connection policy?

 

A.

54

B.

128

C.

256

D.

257

 

Correct Answer: A

 

 

QUESTION 32

Which option is the cause when a DIMM is marked as bad?

 

A.

More than 16000 errors were witnessed during test execution during BIOS.

B.

DIMM Blacklisting is enabled.

C.

The DIMM is missing.

D.

The bank of DIMMs is composed of different size DIMMs.

 

Correct Answer: A

 

 

QUESTION 33

On a Cisco UCS C-Series Rack-Mount Server, which state of the DIMM fault LED indicates a faulty DIMM module?

 

A.

OFF

B.

flashing red

C.

solid amber

D.

flashing amber

E.

flashing blue

 

Correct Answer: C

 

 

 

 

 

QUESTION 34

Which command must you use to find information about system event logs?

 

A.

UCS-TEST-DMZ-A/security #show audit-logs

B.

UCS-TEST-DMZ-A/cimc/log#show entries

C.

UCS-TEST-DMZ-A/system/control-ep#show communication-policy-ctrl

D.

UCS-TEST-DMZ-A#/org/service-profile#show pending-changes detail

 

Correct Answer: B

 

 

QUESTION 35

A customer deploys a new Cisco UCS environment and is deploying new ESXi hosts. The customer fails to establish network connectivity to the KVM console. Which option is the most likely cause of the problem?

 

A.

wrong UUID

B.

missing user rights

C.

IP addressing overlap

D.

NIC pinning

 

Correct Answer: C

 

 

QUESTION 36

You must check the path that vNICs uses to communicate. How can you verify whether a vNIC on a Cisco UCS server is in an active state or a failover state?

 

A.

Run the show interface brief command.

B.

Connect to the adapter and execute the Master Control Program.

C.

Compare the state on both fabric interconnects.

D.

Run the show interface status command.

 

Correct Answer: C

 

 

QUESTION 37

If a server is not associated with a service profile, the activated firmware remains pending. Which two steps should you take? (Choose two.)

 

A.

Manually reboot the server.

B.

Reset the server to a new profile.

C.

Reset the unassociated server to activate the firmware.

D.

Reinitialize the firmware process with Cisco UCS Manager.

E.

Download the firmware and start over.

F.

Shut down gracefully and start over.

 

Correct Answer: AC

 

 

 

 

 

QUESTION 38

Which of these is a supported Cisco C-Series integration topology?

 

A.

clip_image001

B.

clip_image002

C.

clip_image003

D.

clip_image004

 

Correct Answer: B

 

 

QUESTION 39

A Cisco UCS admin is trying to integrate Cisco UCS Manager with Active Directory Authentication. After the configuration is done, the admin is still unable to log in using LDAP credentials. When running a debug on the Fabric Interconnect, this error is displayed:

 

ldap_build_roles_and_locales_from_attr: No attr for usr profile

 

Which step was missed in the configuration?

 

A.

The LDAP provider was not configured correctly.

B.

The proper RBAC role(s) were not assigned to the user.

C.

Cisco UCS Manager 2.1 is required for LDAP integration.

D.

The “Attribute” field in Cisco UCS was left blank.

 

Correct Answer: B

 

 

QUESTION 40

Refer to the exhibit. Which mistake did the UCS administrator make when trying to access the GUI?

 

clip_image005

 

A.

specified the incorrect login domain

B.

did not use the VIP

C.

tried to login before the GUI had fully booted up

D.

password is incorrect

E.

attempted to login to the subordinate cluster peer

 

Correct Answer: E

100% Free Download!
—Download Free Demo:300-180 Demo PDF
100% Pass Guaranteed!
Download 2017 Ensurepass 300-180 Dumps Q&As:291
—Get 10% off your purchase! Copy it:TJDN-947R-9CCD [2017.05.01-2017.05.31]

Ensurepass ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF + VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No

2017 Ensurepass IT Certification PDF and VCE